Get complete information related to latest Diesel Pump Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diesel Pump Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diesel Pump Set Tenders.
Tender For dismantling old and used gi flanged pipe line 50mm i/d /50 mm / s.s. flange, canal t/well, pathera , labour for submersible pump & motor lowering and lifting. /labour for submerseable lowering and ,unlowering / cable change, mata t/well, sehlang, pipe exension canal t/well, pathera ,making new key for 100mm dia s.v 6 feet long 20mm dia gi pipe inculding welding handle ci cap suppoting ,ms patti complete in all respect. /c.i. key for 4 s/valve / water works, baghot ,supply & fixing 100 amp kit kat/100 amp / bus stand t/well, pathera 150 mm/p/f c.i. flange 150mm, canal t/well, sumpwell, pathera 35 bhp starter repair complete including labour charges / banga t/well, sehlang 50 mm/ near bus t/well, pathera ,threading in 6 flange / sumpwell, pathera
Tender For water treatment plant cleaning,purchasing of equipments for wtp, laying of di pipes and sluice valves, construction of sv chamber and phed esr repairing for jamtara nagar panchayat. - labour for site clearance -do--e/i, desilting the supply well, intake well /head works, sump of water supply /sewerage works etc. in wet or dry condition including lifts upto 9 m and lead upto 150m as required beyond the work site,stacking, spreading, including necessary guarding, etc. complete, as directed by e/i, supplying and laying of rapid sand gravity filter sand, supplying and laying of rapid sand gravity filter gravel, supplying of bamboo for scaffolding works, supplying of narial ropes for binding works submersible pumpset, requirement of plumber class-ii for opening & closing of valve & other related works, requirement of electrician grade-ii for making required connections & other related works, hiring of different tools,chain pulley & tackles for cleaning & other works, disposal of excavated earth & filter bed sand, sand (lead 02k+10p=12 km), gravel (22 k.m. lead), tyre coupling (unique 3409-gn tyre coupling for 100hp & 50hp), bosch lithium based grease, graphit gland pack rope 12mm, graphit gland pack rope 16mm, 2.2kw (3hp) foot mounted motor tefc 1500 rpm 3-phase motor for clariflocculator, multi-blade paddles mounted on central shaft driven by foot-mounted geared motor, onload changeover switch 800a,415v, 4 pole, digital voltmeter (0-500v)-3 phase indicator, digital ammeter (0-500a)-3 phase indicator, led indicator lamp or phase light (r/y/b/g), pvc/xlpe insulated pvc sheated heavy duty,armoured lt cable with aluminium conductor voltage upto and including 1100 v, 240sqmm, 3.5 core, 2.5 sqmm isi marked frls pvc insulated, single core copper conductor cable, 1.5 sqmm isi marked frls pvc insulated, single core copper conductor cable, laying of one number pvc insulated and sheated/xlpe power cable of 1.1kv grade of size not exceeding 35sqmm direct in ground including excavation, sand cushioning and refilling the trench, tapered bearing 7316 mcb (large), deep groove ball bearing 6311 mcb (small), chain pulley block hoist 5 tonne, 360 rotation, 3mtr lifting height, pipe wrench, 18 inch taparia adjustable heavy duty pipe wrench, pipe wrench, 14 inch taparia adjustable heavy duty pipe wrench, 1/2" sqaure drive flank drive taparia goti 22mm socket set, 1/2" sqaure drive flank drive taparia goti 20mm socket set, rachet wrench, 18 inch single sided rachet wrench, 1/2 inch drill bit for threading di/ci pipe, tata agrico hammer -dfs- 2.5kg, 6 inch tyton epdm/sbr rubber gasket for 150mm di pipe conforming to is:5382 isi mark, 4 inch tyton epdm/sbr rubber gasket for 100mm di pipe conforming to is:5382 isi mark, 6 inch di end cap flanged type for 150mm di pipe, 4 inch di end cap flanged type for 100mm di pipe, epdm rubber gasket for non-return valve, earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 150mm), earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 100mm), earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 100mm repair), earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches wit
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & dieselpumpset complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f